{"product_id":"truma-water-connection-set-frost-control-jg-connectors","title":"Truma Water Connection Set FrostControl JG 34020-00238 | Kit","description":"\u003ch2\u003eTruma Water Connection Set, Frost Control and JG Connectors\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp data-start=\"322\" data-end=\"558\"\u003eThe \u003cstrong data-start=\"326\" data-end=\"395\"\u003eTruma Water Connection Set FrostControl JG (Part No. 34020-00238)\u003c\/strong\u003e is a genuine Truma water system installation kit designed for caravans, campervans and motorhomes fitted with \u003cstrong data-start=\"506\" data-end=\"555\"\u003eTruma Combi or Truma Boiler hot water systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"560\" data-end=\"830\"\u003eThe kit includes the \u003cstrong data-start=\"581\" data-end=\"655\"\u003eTruma FrostControl drain valve and John Guest (JG) push-fit connectors\u003c\/strong\u003e, allowing it to be integrated directly into \u003cstrong data-start=\"700\" data-end=\"734\"\u003e12 mm fixed water pipe systems\u003c\/strong\u003e commonly used in modern caravan plumbing installations. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"832\" data-end=\"1106\"\u003eThe FrostControl valve protects the water heater and pipework from frost damage by \u003cstrong data-start=\"915\" data-end=\"996\"\u003eautomatically draining the water system when temperatures drop to around 3 °C\u003c\/strong\u003e, preventing water inside the boiler from freezing and causing damage. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1108\" data-end=\"1265\"\u003eIt also acts as a \u003cstrong data-start=\"1126\" data-end=\"1151\"\u003epressure relief valve\u003c\/strong\u003e, automatically releasing excess pressure when the boiler heats the water. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1267\" data-end=\"1392\"\u003eThis makes the water connection set an essential safety component for caravans and motorhomes operating in colder conditions.\u003c\/p\u003e\n\u003chr data-start=\"1394\" data-end=\"1397\"\u003e\n\u003ch2 data-start=\"1399\" data-end=\"1430\"\u003eWhy Choose This Spare Part\u003c\/h2\u003e\n\u003cul data-start=\"1432\" data-end=\"1904\"\u003e\n\u003cli data-start=\"1432\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1434\" data-end=\"1495\"\u003e\u003cstrong data-start=\"1434\" data-end=\"1492\"\u003eOriginal Truma water system kit – Part No. 34020-00238\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1496\" data-end=\"1614\"\u003e\n\u003cp data-start=\"1498\" data-end=\"1614\"\u003eProvides \u003cstrong data-start=\"1507\" data-end=\"1573\"\u003eautomatic frost protection for Truma boilers and Combi heaters\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1615\" data-end=\"1719\"\u003e\n\u003cp data-start=\"1617\" data-end=\"1719\"\u003eDesigned for \u003cstrong data-start=\"1630\" data-end=\"1678\"\u003e12 mm John Guest push-fit water pipe systems\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1720\" data-end=\"1835\"\u003e\n\u003cp data-start=\"1722\" data-end=\"1835\"\u003eIncludes the \u003cstrong data-start=\"1735\" data-end=\"1794\"\u003eFrostControl safety drain valve and connection fittings\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1836\" data-end=\"1904\"\u003e\n\u003cp data-start=\"1838\" data-end=\"1904\"\u003eSuitable for \u003cstrong data-start=\"1851\" data-end=\"1903\"\u003ecaravans, motorhomes and campervan water systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1906\" data-end=\"2049\"\u003eThe FrostControl valve automatically drains the boiler when freezing temperatures are detected, protecting the water system from costly damage.\u003c\/p\u003e\n\u003chr data-start=\"2051\" data-end=\"2054\"\u003e\n\u003ch2 data-start=\"2056\" data-end=\"2073\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"2075\" data-end=\"2372\"\u003e\n\u003cli data-start=\"2075\" data-end=\"2140\"\u003e\n\u003cp data-start=\"2077\" data-end=\"2140\"\u003eWater connection kit with \u003cstrong data-start=\"2103\" data-end=\"2138\"\u003eTruma FrostControl safety valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2141\" data-end=\"2207\"\u003e\n\u003cp data-start=\"2143\" data-end=\"2207\"\u003eCompatible with \u003cstrong data-start=\"2159\" data-end=\"2205\"\u003eTruma Combi and Truma Boiler water heaters\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2208\" data-end=\"2267\"\u003e\n\u003cp data-start=\"2210\" data-end=\"2267\"\u003eDesigned for \u003cstrong data-start=\"2223\" data-end=\"2265\"\u003e12 mm John Guest push-fit pipe systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2268\" data-end=\"2328\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2328\"\u003eAutomatic \u003cstrong data-start=\"2280\" data-end=\"2326\"\u003efrost protection and pressure relief valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2329\" data-end=\"2372\"\u003e\n\u003cp data-start=\"2331\" data-end=\"2372\"\u003eGenuine \u003cstrong data-start=\"2339\" data-end=\"2372\"\u003eTruma part number 34020-00238\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2374\" data-end=\"2377\"\u003e\n\u003ch2 data-start=\"2379\" data-end=\"2408\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2410\" data-end=\"3066\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2410\" data-end=\"2437\"\u003e\n\u003ctr data-start=\"2410\" data-end=\"2437\"\u003e\n\u003cth data-start=\"2410\" data-end=\"2426\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2426\" data-end=\"2437\" data-col-size=\"md\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2448\" data-end=\"3066\"\u003e\n\u003ctr data-start=\"2448\" data-end=\"2509\"\u003e\n\u003ctd data-start=\"2448\" data-end=\"2463\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"2463\" data-end=\"2509\" data-col-size=\"md\"\u003eTruma Water Connection Set FrostControl JG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2510\" data-end=\"2556\"\u003e\n\u003ctd data-start=\"2510\" data-end=\"2537\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2512\" data-end=\"2536\"\u003eOriginal Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2537\" data-end=\"2556\"\u003e\u003cstrong data-start=\"2539\" data-end=\"2554\"\u003e34020-00238\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2557\" data-end=\"2581\"\u003e\n\u003ctd data-start=\"2557\" data-end=\"2572\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-start=\"2572\" data-end=\"2581\" data-col-size=\"md\"\u003eTruma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2582\" data-end=\"2645\"\u003e\n\u003ctd data-start=\"2582\" data-end=\"2597\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-start=\"2597\" data-end=\"2645\" data-col-size=\"md\"\u003eWater system connection kit with frost valve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2646\" data-end=\"2703\"\u003e\n\u003ctd data-start=\"2646\" data-end=\"2667\" data-col-size=\"sm\"\u003ePipe Compatibility\u003c\/td\u003e\n\u003ctd data-start=\"2667\" data-end=\"2703\" data-col-size=\"md\"\u003e12 mm John Guest push-fit system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2704\" data-end=\"2760\"\u003e\n\u003ctd data-start=\"2704\" data-end=\"2726\" data-col-size=\"sm\"\u003eOpening Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2726\" data-end=\"2760\" data-col-size=\"md\"\u003eApprox. 3 °C (automatic drain)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2761\" data-end=\"2799\"\u003e\n\u003ctd data-start=\"2761\" data-end=\"2783\" data-col-size=\"sm\"\u003eClosing Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2783\" data-end=\"2799\" data-col-size=\"md\"\u003eApprox. 7 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2800\" data-end=\"2835\"\u003e\n\u003ctd data-start=\"2800\" data-end=\"2824\" data-col-size=\"sm\"\u003eMaximum Pump Pressure\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2824\" data-end=\"2835\"\u003e2.8 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2836\" data-end=\"2873\"\u003e\n\u003ctd data-start=\"2836\" data-end=\"2862\" data-col-size=\"sm\"\u003eMaximum System Pressure\u003c\/td\u003e\n\u003ctd data-start=\"2862\" data-end=\"2873\" data-col-size=\"md\"\u003e4.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2874\" data-end=\"2934\"\u003e\n\u003ctd data-start=\"2874\" data-end=\"2888\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-start=\"2888\" data-end=\"2934\" data-col-size=\"md\"\u003eTruma boiler \/ Combi water heater plumbing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2935\" data-end=\"2983\"\u003e\n\u003ctd data-start=\"2935\" data-end=\"2950\" data-col-size=\"sm\"\u003eVehicle Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2950\" data-end=\"2983\"\u003eCaravan, campervan, motorhome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2984\" data-end=\"3066\"\u003e\n\u003ctd data-start=\"2984\" data-end=\"3005\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2986\" data-end=\"3004\"\u003eProduct Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"3005\" data-end=\"3066\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"3007\" data-end=\"3026\"\u003eApprox. 0.28 kg\u003c\/strong\u003e \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"3068\" data-end=\"3071\"\u003e\n\u003ch2 data-start=\"3073\" data-end=\"3111\"\u003eWhere and How to Fit This Product\u003c\/h2\u003e\n\u003cp data-start=\"3113\" data-end=\"3265\"\u003eThe \u003cstrong data-start=\"3117\" data-end=\"3177\"\u003eTruma Water Connection Set FrostControl JG (34020-00238)\u003c\/strong\u003e is installed \u003cstrong data-start=\"3191\" data-end=\"3264\"\u003ein the cold water inlet line feeding the Truma boiler or Combi heater\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-start=\"3267\" data-end=\"3294\"\u003eInstallation Overview\u003c\/h3\u003e\n\u003col data-start=\"3296\" data-end=\"3940\"\u003e\n\u003cli data-start=\"3296\" data-end=\"3375\"\u003e\n\u003cp data-start=\"3299\" data-end=\"3375\"\u003eIdentify the \u003cstrong data-start=\"3312\" data-end=\"3372\"\u003ecold water supply pipe leading to the Truma water heater\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3376\" data-end=\"3448\"\u003e\n\u003cp data-start=\"3379\" data-end=\"3448\"\u003eCut the \u003cstrong data-start=\"3387\" data-end=\"3407\"\u003e12 mm water pipe\u003c\/strong\u003e at the appropriate installation point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3449\" data-end=\"3527\"\u003e\n\u003cp data-start=\"3452\" data-end=\"3527\"\u003eInsert the \u003cstrong data-start=\"3463\" data-end=\"3510\"\u003eJohn Guest push-fit connectors from the kit\u003c\/strong\u003e into the pipe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3528\" data-end=\"3597\"\u003e\n\u003cp data-start=\"3531\" data-end=\"3597\"\u003eInstall the \u003cstrong data-start=\"3543\" data-end=\"3594\"\u003eFrostControl valve vertically in the water line\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3598\" data-end=\"3692\"\u003e\n\u003cp data-start=\"3601\" data-end=\"3692\"\u003eEnsure the \u003cstrong data-start=\"3612\" data-end=\"3643\"\u003edrain outlet faces downward\u003c\/strong\u003e so water can drain safely outside the vehicle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3693\" data-end=\"3861\"\u003e\n\u003cp data-start=\"3696\" data-end=\"3861\"\u003eSecure the valve inside the \u003cstrong data-start=\"3724\" data-end=\"3764\"\u003esame compartment as the water heater\u003c\/strong\u003e, allowing it to sense the ambient temperature correctly. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3862\" data-end=\"3940\"\u003e\n\u003cp data-start=\"3865\" data-end=\"3940\"\u003eTest the system for leaks and confirm the valve opens and closes correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"3942\" data-end=\"4103\"\u003eThe valve should be mounted \u003cstrong data-start=\"3970\" data-end=\"4015\"\u003eclose to the Truma boiler or Combi heater\u003c\/strong\u003e, as it needs to detect the same temperature conditions as the water heater compartment.\u003c\/p\u003e\n\u003cp data-start=\"4105\" data-end=\"4254\"\u003eInstallation should be carried out by a \u003cstrong data-start=\"4145\" data-end=\"4202\"\u003equalified caravan technician or experienced installer\u003c\/strong\u003e, particularly when modifying water system pipework.\u003c\/p\u003e\n\u003chr data-start=\"4256\" data-end=\"4259\"\u003e\n\u003ch2 data-start=\"4261\" data-end=\"4281\"\u003eWhat’s Included\u003c\/h2\u003e\n\u003cul data-start=\"4283\" data-end=\"4469\"\u003e\n\u003cli data-start=\"4283\" data-end=\"4324\"\u003e\n\u003cp data-start=\"4285\" data-end=\"4324\"\u003e\u003cstrong data-start=\"4285\" data-end=\"4322\"\u003eTruma FrostControl JG drain valve\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4325\" data-end=\"4369\"\u003e\n\u003cp data-start=\"4327\" data-end=\"4369\"\u003e\u003cstrong data-start=\"4327\" data-end=\"4367\"\u003eJohn Guest 12 mm push-fit connectors\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4370\" data-end=\"4469\"\u003e\n\u003cp data-start=\"4372\" data-end=\"4469\"\u003eWater connection components and fittings for installation \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4471\" data-end=\"4542\"\u003e\u003cem data-start=\"4471\" data-end=\"4542\"\u003e(Additional pipework and water hoses are not included unless stated.)\u003c\/em\u003e\u003c\/p\u003e\n\u003chr data-start=\"4544\" data-end=\"4547\"\u003e\n\u003ch2 data-start=\"4549\" data-end=\"4578\"\u003eWhy Buy This Spare Part?\u003c\/h2\u003e\n\u003cp data-start=\"4580\" data-end=\"4949\"\u003eThe \u003cstrong data-start=\"4584\" data-end=\"4644\"\u003eTruma Water Connection Set FrostControl JG (34020-00238)\u003c\/strong\u003e is an essential safety component for caravans and motorhomes fitted with Truma water heaters. By automatically draining the boiler during freezing temperatures and releasing excess pressure when needed, it helps protect the water system from frost damage and prolongs the life of the heater and pipework.\u003c\/p\u003e","brand":"Caravan-Life","offers":[{"title":"Default Title","offer_id":61258078683466,"sku":"36100-52M","price":74.95,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0839\/6944\/2122\/files\/SWLS22326_Truma_Frost_Control_Kit.webp?v=1772634305","url":"https:\/\/caravan-life.co.uk\/products\/truma-water-connection-set-frost-control-jg-connectors","provider":"Caravan-Life","version":"1.0","type":"link"}